Heat Shrink Insulating Tubing
Offering you a complete choice of products which include extruded medium wall tubing with hot melt adhesive lined, stress control tubing, elastomer triple layer screened insulating composite tubing, heavy wall insulation tubing with hot melt adhesive coating, medium wall insulation tubing with hot melt adhesive coating and anti-tracking insulation tubing.
Extruded Medium Wall Tubing With Hot Melt Adhesive Lined
Approx. Price: Rs 500 / MeterGet Latest Price Product Details:
| Length | 1.0 m |
| Thickness | 1.8 mm |
| Color | Black |
| Inner Diameter As Supplied | 8 mm |
| Inner Diameter After Fully Recovered | 2 mm |
| Application | LV & MV Cable Joints & Terminations |
| Product Code | PRTM-1 |
Details:
- It is a general-purpose medium wall tubing supplied with (co-extruded) or without adhesive coating. It is used for cable outer sheath replacement, sealing and corrosion protection or uncoated as an insulating material or protective cover for LV & MV Cables.
- The tubing is normally used in LV & MV Cable Joints & terminations from 1kV onwards.
- It is available in various sizes, generally expanded in the ratio 3+:1 to make it range taking.
Technical Details:| Product | Size | As Supplied | After Recovered | Standard Length |
| Code | (mm) | (mm) | (mm) |
| | | D*(Min.) | D*(Max.) | W(Min.) |
| PRTM-1 | 08/02 | 8 | 2 | 1.8 | 1.0-1.5m |
| PRTM-2 | 12/03 | 12 | 3 | 1.9 | 1.0-1.5m |
| PRTM-3 | 16/05 | 16 | 5 | 1.9 | 1.0-1.5m |
| PRTM-4 | 19/05 | 19 | 5 | 1.9 | 1.0-1.5m |
| PRTM-5 | 22/06 | 22 | 6 | 2.1 | 1.0-1.5m |
| PRTM-6 | 28/06 | 28 | 6 | 2.6 | 1.0-1.5m |
| PRTM-7 | 33/08 | 33 | 8 | 2.4 | 1.0-1.5m |
| PRTM-8 | 40/12 | 40 | 12 | 2.4 | 1.0-1.5m |
| PRTM-9 | 45/12 | 45 | 12 | 2.4 | 1.0-1.5m |
| PRTM-10 | 55/16 | 55 | 16 | 2.4 | 1.0-1.5m |
| PRTM-11 | 65/19 | 65 | 19 | 2.6 | 1.0-1.5m |
Approx. Price: Rs 600 / MeterGet Latest Price Product Details:
| Size | 1/2 inch |
| Color | Black |
| Inner Diameter As Supplied | 26 mm |
| Inner Diameter After Fully Recovered | 10 mm |
| Thickness | 2.1 mm |
| Standard Length | 15m / Spool |
| Product Code | PSCT-21 |
Details:
- The Stress control tubing provides the stress control function for cable terminations & joints of solid dielectric XLPE, rubber, PVC or PILC (MI/MIND) insulated screened cables.
- The tubing is normally used in MV Cable Joints & terminations > 3.3 kV. It is available in various sizes, generally expanded in the ratio 2+:1 to make it range taking.
- Design software for customised applications / selection available.
Technical Details:
| PSCT UPTO 24KV |
| Product |
Size |
As Supplied |
After Recovered |
Standard Length |
| Code |
(mm) |
(mm) |
(mm) |
| |
|
D*(Min.) |
D*(Max.) |
W(Min.) |
| PSCT-21 |
26/10 |
26 |
10 |
2.1 |
15m / Spool or 1.0-1.5m |
| PSCT-22 |
30/12 |
30 |
12 |
2.2 |
15m / Spool or 1.0-1.5m |
| PSCT-23 |
35/15 |
35 |
15 |
2.3 |
15m / Spool or 1.0-1.5m |
| PSCT-24 |
40/16 |
40 |
16 |
2.4 |
15m / Spool or 1.0-1.5m |
| PSCT-25 |
47/18 |
47 |
18 |
2.4 |
15m / Spool or 1.0-1.5m |
| PSCT-26 |
55/21 |
55 |
21 |
2.4 |
15m / Spool or 1.0-1.5m |
| PSCT-27 |
65/25 |
65 |
25 |
2.4 |
15m / Spool or 1.0-1.5m |
| PSCT-28 |
75/30 |
75 |
30 |
2.4 |
15m / Spool or 1.0-1.5m |
Elastomer Triple Layer Screened Insulating Composite Tubing
Approx. Price: Rs 1,500 / MeterGet Latest Price Product Details:
| Inner Diameter As Supplied | 36 mm |
| Inner Diameter After Fully Recovered | 12 mm |
| Thickness | 7.3 mm |
| Length | 1.0 mm |
| Application | MV & HV Cable Joints |
Details:
- It is a triple extruded composite joint sleeve. The combination of the inner elastomeric layer and the heat-shrink middle layer provides a reliable insulation replacement over the connection of jointed cables. The black outer layer is conductive and provides the screening function.
- The tubing is normally used in MV & HV (72kV) Cable Joints > 1kV.
- It is available in various sizes, generally expanded in the ratio 2.5+:1 to make it range taking.
Technical Details:
| Product |
Size |
As Supplied |
After Recovered |
Standard Length |
| Code |
(mm) |
(mm) |
| |
D*(Min.) |
D*(Max.) |
W(Min.) |
| PTRT-1 |
36/12 |
36 |
12 |
7.3 |
1.0-1.22m |
| PTRT-2 |
46/15 |
46 |
15 |
7.3 |
1.0-1.22m |
| PTRT-3 |
50/18 |
50 |
18 |
7.3 |
1.0-1.22m |
| PTRT-4 |
56/21 |
56 |
21 |
2.9 |
1.0-1.22m |
| PTRT-5 |
62/25 |
62 |
25 |
7.3 |
1.0-1.22m |
| PTRT-6 |
70/30 |
70 |
30 |
7.3 |
1.0-1.22m |
| PTRT-7 |
80/36 |
80 |
36 |
7.3 |
1.0-1.22m |
| PTRT-8 |
95/40 |
95 |
40 |
7.3 |
1.0-1.22m |
| PTRT-9 |
120/50 |
120 |
50 |
7.3 |
1.0-1.22m |
Heavy Wall Insulation Tubing With Hot Melt Adhesive Coating
Approx. Price: Rs 650 / MeterGet Latest Price Product Details:
| Inner Diameter As Supplied | 9 mm |
| Inner Diameter After Fully Recovered | 3 mm |
| Thickness | 2.0 mm |
| Length | 1.0 mm |
| Product Code | PRA3-1 |
Details:
- It is a general-purpose medium wall tubing supplied with (co-extruded) or without adhesive coating. It is used for cable outer sheath replacement, sealing and corrosion protection or uncoated as an insulating material or protective cover for LV & MV Cables.
- The tubing is normally used in LV & MV Cable Joints & terminations from 1kV onwards.
- It is available in various sizes, generally expanded in the ratio 3+:1 to make it range taking.
Technical Details:
| PRA3(WITH HOT MELT ADHESIVE) |
| Product |
Size |
As Supplied |
After Recovered |
Standard Length |
| Code |
(mm) |
(mm) |
(mm) |
| |
|
D*(Min.) |
D*(Max.) |
W(Min.) |
| PRA3-1 |
09/03 |
9 |
3 |
2 |
1.0-1.5m |
| PRA3-2 |
15/04 |
15 |
4 |
2.4 |
1.0-1.5m |
| PRA3-3 |
22/06 |
22 |
6 |
2.7 |
1.0-1.2m |
| PRA3-4 |
33/08 |
33 |
8 |
3.2 |
1.0-1.5m |
| PRA3-5 |
45/12 |
45 |
12 |
4 |
1.0-1.5m |
| PRA3-6 |
55/16 |
55 |
16 |
4 |
1.0-1.5m |
| PRA3-7 |
65/19 |
65 |
19 |
4 |
1.0-1.5m |
| PRA3-8 |
75/22 |
75 |
22 |
4 |
1.0-1.5m |
| PRA3-9 |
85/25 |
85 |
25 |
4.2 |
1.0-1.5m |
| PRA3-10 |
95/29 |
95 |
29 |
4.2 |
1.0-1.5m |
| PRA3-11 |
105/25 |
105 |
25 |
4.2 |
1.0-1.5m |
| PRA3-12 |
115/34 |
115 |
34 |
4.2 |
1.0-1.5m |
Medium Wall Insulation Tubing With Hot Melt Adhesive Coating
Approx. Price: Rs 500 / MeterGet Latest Price Product Details:
| Inner Diameter As Supplied | 8 mm |
| Inner Diameter After Fully Recovered | 2 mm |
| Thickness | 1.8 mm |
| Length | 1.0 m |
| Application | LV & MV Cable Joints & Terminations |
| Product Code | PRA2-1 |
Details:
- It is a general-purpose medium wall tubing supplied with (co-extruded) or without adhesive coating. It is used for cable outer sheath replacement, sealing and corrosion protection or uncoated as an insulating material or protective cover for LV & MV Cables.
- The tubing is normally used in LV & MV Cable Joints & terminations from 1kV onwards.
- It is available in various sizes, generally expanded in the ratio 3+:1 to make it range taking.
Technical Details:
| Product |
Size |
As Supplied |
After Recovered |
Standard Length |
| Code |
(mm) |
(mm) |
(mm) |
| |
|
D*(Min.) |
D*(Max.) |
W(Min.) |
| PRA2-1 |
08/02 |
8 |
2 |
1.8 |
1.0-1.5m |
| PRA2-2 |
12/03 |
12 |
3 |
1.8 |
1.0-1.5m |
| PRA2-3 |
16/05 |
16 |
5 |
2.1 |
1.0-1.5m |
| PRA2-4 |
22/06 |
22 |
6 |
2.4 |
1.0-1.5m |
| PRA2-5 |
28/06 |
28 |
6 |
2.7 |
1.0-1.5m |
| PRA2-6 |
33/8 |
33 |
7 |
2.6 |
1.0-1.5m |
| PRA2-7 |
40/12 |
40 |
12 |
2.6 |
1.0-1.5m |
| PRA2-8 |
55/16 |
55 |
16 |
2.7 |
1.0-1.5m |
| PRA2-9 |
65/19 |
65 |
19 |
2.9 |
1.0-1.5m |
| PRA2-10 |
75/22 |
75 |
22 |
3 |
1.0-1.5m |
| PRA2-11 |
95/25 |
95 |
25 |
3.6 |
1.0-1.5m |
| PRA2-12 |
115/34 |
115 |
34 |
3.5 |
1.0-1.5m |
| PRA2-13 |
140/42 |
140 |
42 |
3.3 |
1.0-1.5m |
| PRA2-14 |
160/50 |
160 |
50 |
3.3 |
1.0-1.5m |
Anti-Tracking Insulation Tubing
Approx. Price: Rs 400 / MeterGet Latest Price Product Details:
| Thickness | 25 mm |
| Application | MV Cable Terminations |
| Length | 30 m/ spool |
| Finishing | Color Coated |
| Inner Diameter As Supplied | 19 mm |
| Inner Diameter After Fully Recovered | 6 mm |
Details:
- In areas of extreme environmental conditions and high electrical stress, the tubing protects Cable insulation & or substrates from erosion caused by leakage current. The antitracking sealant provides a moisture proof environmental seal to the substrate.
- The tubing is normally used in Cable Terminations for voltages > 1 kV.
- It is available in various sizes, generally expanded in the ratio 3:1 to make it range taking.
Technical Details:| Product | Size | As Supplied | After Recovered | Standard Length |
| Code | (mm) | (mm) |
| | D*(Min.) | D*(Max.) | W(Min.) |
| PAT-1 | 19/06 | 19 | 6 | 2.5 | 30m/spool or 0.5-1.5m |
| PAT-2 | 30/10 | 30 | 10 | 2.9 | 30m/spool or 0.5-1.5m |
| PAT-3 | 38/12 | 38 | 12 | 2.9 | 30m/spool or 0.5-1.5m |
| PAT-4 | 40/16 | 40 | 16 | 2.9 | 30m/spool or 0.5-1.5m |
| PAT-5 | 49/16 | 49 | 16 | 2.9 | 30m/spool or 0.5-1.5m |
| PAT-6 | 55/18 | 55 | 18 | 2.9 | 30m/spool or 0.5-1.5m |
| PAT-7 | 65/21 | 65 | 21 | 3.3 | 30m/spool or 0.5-1.5m |
| PAT-8 | 75/25 | 75 | 25 | 3.5 | 30m/spool or 0.5-1.5m |
| PAT-9 | 85/29 | 85 | 29 | 3.5 | 30m/spool or 0.5-1.5m |
| PAT-10 | 100/40 | 100 | 40 | 4 | 30m/spool or 0.5-1.5m |
| PAT-11 | 130/50 | 130 | 50 | 4 | 30m/spool or 0.5-1.5m |
Approx. Price: Rs 550 / MeterGet Latest Price Product Details:
| Thickness | 3.2 mm |
| Material | Insulating Polymer |
| Application | MV Cable Joints |
| Inner Diameter As Supplied | 35 mm |
| Inner Diameter After Fully Recovered | 12 mm |
| Finishing | Color Coated |
| Length | 1.0 m |
Details:
- The tubing provides an excellent insulating cover over the connection of jointed single and multicore cables. Tubing is used in joints for cables with solid dielectric XLPE, rubber, PVC or PILC (MI/MIND) insulation.
- The tubing is normally used in Cable Joints for voltages > 1 kV.
- It is available in various sizes, generally expanded in the ratio 2.5+:1 to make it range taking.
Technical Details:
| Product |
Size |
As Supplied |
After Recovered |
Standard Length |
| Code |
(mm) |
(mm) |
(mm) |
| |
|
D*(Min.) |
D*(Max.) |
W(Min.) |
| PGT-1 |
35/12 |
35 |
12 |
3.2 |
1.0-1.5m |
| PGT-2 |
45/14 |
45 |
14 |
3.5 |
1.0-1.5m |
| PGT-3 |
52/15 |
52 |
15 |
3.9 |
1.0-1.5m |
| PGT-4 |
55/18 |
55 |
18 |
3.9 |
1.0-1.5m |
| PGT-5 |
66/20 |
66 |
20 |
4.4 |
1.0-1.5m |
| PGT-6 |
75/25 |
75 |
25 |
4.7 |
1.0-1.5m |
| PGT-7 |
95/30 |
95 |
30 |
4.7 |
1.0-1.5m |
Semi Conductive Double Layer Screened Insulating Composite Tubing
Approx. Price: Rs 900 / MeterGet Latest Price Product Details:
| Thickness | 5.4 mm |
| Inner Diameter As Supplied | 36 mm |
| Inner Diameter After Fully Recovered | 12 mm |
| Length | 1.0 m |
| Product Code | PDWT-1 |
Details:- It is a screened insulating, composite tubing. The inner layer provides an excellent insulating layer over the connection of jointed single and multicore cables. The outer layer provides a conductive layer (screen function) for joints used on cables with XLPE or rubber or PVC insulation and on paper insulated cables.
- The tubing is normally used in MV Cable Joints > 1kV.
- It is available in various sizes, generally expanded in the ratio 2.5+:1 to make it range taking.
Technical Details:| Product | Size | As Supplied | After Recovered | Standard Length |
| Code | (mm) | (mm) | (mm) |
| | | D*(Min.) | D*(Max.) | W(Min.) |
| PDWT-1 | 36/12 | 36 | 12 | 5.4 | 1.0-1.2m |
| PDWT-2 | 45/15 | 45 | 15 | 5.4 | 1.0-1.2m |
| PDWT-3 | 55/18 | 55 | 18 | 5.4 | 1.0-1.2m |
| PDWT-4 | 65/22 | 65 | 22 | 6 | 1.0-1.2m |
| PDWT-5 | 73/26 | 73 | 26 | 6 | 1.0-1.2m |
| PDWT-6 | 85/30 | 85 | 30 | 6 | 1.0-1.2m |
| PDWT-7 | 95/34 | 95 | 34 | 6 | 1.0-1.2m |
| PDWT-8 | 100/38 | 100 | 38 | 6 | 1.0-1.2m |
| PDWT-9 | 115/34 | 115 | 34 | 6 | 1.0-1.2m |
| PDWT-10 | 120/45 | 120 | 45 | 6.1 | 1.0-1.2m |
Elastomeric Double Layer Tube
Approx. Price: Rs 600 / MeterGet Latest Price Product Details:
| Thickness | 3.9 mm |
| Inner Diameter As Supplied | 42 mm |
| Inner Diameter After Fully Recovered | 16 mm |
| Standard Length | 1.5 m |
| Usage/Application | MV Cable Joints |
| Product Code | PEGT-1 |
Details:- The tubing provides an excellent insulating cover over the connection of jointed single and multicore cables. Tubing is used in joints for cables with solid dielectric XLPE, rubber, PVC or PILC (MI/MIND) insulation. The tubing is a dual wall tubing with an inner Elastomeric Layer and a heat shrink outer layer.
- The tubing is normally used in Cable Joints for voltages > 1 kV.
- It is available in various sizes, generally expanded in the ratio 2.4+:1 to make it range taking.
Technical Details:| PEGT |
| Product | Size | H | H | W1 | W2 | W1+W2 | P |
| Code | (mm) | A | B | B | B | B | Standard Length |
| | | (mm) | (mm) | (mm) | (mm) | (Mm) | |
| | | Min | Max | Nom | Min | Min | |
| PEGT-1 | 42/16 | 42 | 16 | 1.9 | 2 | 3.9 | 0.38-1.5m |
| PEGT-2 | 54/21 | 54 | 21 | 1.9 | 2 | 3.9 | 0.38-1.5m |
| PEGT-3 | 62/26 | 62 | 26 | 1.9 | 2 | 3.9 | 0.38-1.5m |
| PEGT-4 | 55/20 | 55 | 20 | 2.9 | 3 | 5.9 | 0.38-1.22m |
| PEGT-5 | 62/25 | 62 | 25 | 2.9 | 3 | 5.9 | 0.38-1.22m |
| PEGT-6 | 70/30 | 70 | 30 | 2.9 | 3 | 5.9 | 0.38-1.22m |
| PEGT-7 | 80/34 | 80 | 34 | 2.9 | 3 | 5.9 | 0.38-1.22m |
| PEGT-8 | 95/40 | 95 | 40 | 2.9 | 3 | 5.9 | 0.38-1.22m |